<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>alproof</ParameterFamily>
<LongName>
load_with_stepper
</LongName>
<Name>
lws
</Name>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Trendsetter_400/800_Proofing</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
This parameter is obsolete after Spectrum firmware version 1.1. The firmware
will always load with the vacuum roller's stepper motor.
</text></DescriptionText>
<DescriptionText><text>
Selects whether the vacuum roller's stepper motor or the drum motor should be
the driving force while loading media onto the drum.
</text></DescriptionText>
<DescriptionText><text>
Setting this to 0 results in the vacuum roller's stepper motor going idle when
the drum and vacuum roller are in contact during media loading, and uses the
drum motor to rotate the drum and all other contacting rollers.  The resulting
force transmitted from the drum to the vacuum &amp; other rollers using this
method could cause the media to slip on the surface of the drum, and get
positioned incorrectly.
</text></DescriptionText>
<DescriptionText><text>
Setting this to 1 results in the drum going nearly idle, with only a small
torque applied, and the vacuum roller's stepper motor is then used to rotate the
drum and the other rollers while winding media onto the drum.
</text></DescriptionText>
</Description>
<Type>
byte
</Type>
<Default>
<UnnumberedList>
<li>1 (obsolete after version 1.1)</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 1 (no units)</li>
</UnnumberedList>
</Range>
<ArraySize>
</ArraySize>
<Notes>
<DescriptionText><text>
</text></DescriptionText>
</Notes>
<Partition>
cfg
</Partition>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../nvs/alproof_cal_torq.xml</LinkAddress><LinkTitle>NVS: alproof torq</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:36:28 2008 PST
</Updated>
<Links>
</Links>
</Parameter>